DEUTSCH Drucken   
PRODUCTS    APPLICATIONS    INNOVATIONS     
Topas GmbH
Oskar-Röder-Str. 12
D-01237 Dresden
Tel.: +49 (351) 2166 430
Fax: +49 (351) 2166 4355
E-mail: 

Image Brochure
Information - Reflection - Motivation
Imagebroschüre Deutsch   Imagebroschüre Deutsch   Imagebroschüre Deutsch   Imagebroschüre Deutsch
Imagebroschüre Deutsch   Imagebroschüre Deutsch   Imagebroschüre Deutsch   Imagebroschüre Japanisch
EVENTS   
CONTACT   
SERVICE   
IMPRINT   
LOGIN   
New Products

LAP 322 Laser Aerosol Particle Size SpectrometerHDS 561 
High Dilution System
 
PAP 612
Process Aerosol Photometer
  • Enhanced particle size range: 0,2-40µm
  • High particle size resolution: max. 128 channels
  • Excellent classification accuracy and reproducibility
  • High counting efficiency already at 0,2µm
  • Sensor and signal acquisition are arranged in one handy, robust housing - mobility
  • Incl. powerful and extensive control and analysing software PASWin
  • Reliable and very high single-stage dilution
  • Dilution ratio adjustable in very wide range (100 to 100,000)
  • Customizable to volume flow rates of different particle counters (2.8 to 100 l/min)
  • Capability of remote control of present dilution factor and adjustment of different dilution factors
  • Only very small pressure loss
  • In-situ-concentration measurement in blow-by aerosols, suspensions and emulsions
  • Additonal particle size information by use of two wavelengths and two scattering angles
  • Detection and indication  (status LED) of gushes of oil or condensation
  • Very small and robust design
Laser Aerosol Particle Size Spectrometer LAP 322High Dilution System for Aerosols HDS 561 with Adjustable Diluting RatioProcess aerosol photometer PAP 612 for blow-by
ADD 536            
Aerosol Distribution/Dilution System
GMS 141
Gravimetric Measurement System
MBP 116
Manual Filter Media Test Rig
  • Designed to comply with the requirements of the German standard DIN 1946-4 and the Swiss guideline SWKI 99-3 (OP-room validation)
  • Reliable particle generation rate with an excellent long term stability (particles/time)
  • Internal adjustable aerosol dilution ratio for direct connection of a particle counter (e.g. Topas LAP 340) used for controlling a stable particle rate
  • Uniform aerosol distribution to six outlet ports
  • Comfortable detection of oil content in blow-by after oil mist separators with a filter blank sheet or filter cartridge directly on engines or engine test stands
  • Two independent sections: bypass and measuring. Running up to the working point over bypass section and measuring over measuring section. Prevention of undesirable filter charging.
  • Switching between both sections with pneumatic ball valves;
    feature: manual or automatic switching (by default time or differential pressure)
  • Heatable absolute filter box in order to avoid condensation (up to 110 °C)
  • Test of plane filter media
  • Reliable timesaving testing of gravimetric filter efficiency, dust holding capacity, differential pressure and fractional filter efficiency
  • Simple operation in combination with a robust, space saving design, modular setup (benchtop model)
  • Integrated solid aerosol generator for smallest feeding rates starting at 70 mg/h
Aerosol Distribution and Dilution System ADD 536Gravimetric Measurement System GMS 141Manual Filter Media Test Rig MBP116